E-mail Home Return

 

INDUCTION HEAT TREATMENT

  The roll bodies hardening is executed in the automated induction hardening facility with induction heating. This provides recurrence of the hardening results. Hardness variation does not exceed 2-3 HSD. The work rolls have the depth of the effective case up to 45 mm, the backup rolls - up to 60 mm along the radius.
  To harden the necks for the bodies hardness of 45 HSD the technology of hardening with high-frequency heating is introduced in the Company.